Category: Electrical Diagnostics

Electrical fault-finding, testing and diagnostics on refrigeration and air conditioning systems.

Electrical Diagnostics Technical

What Load Shedding Does to Your Refrigeration Equipment

  • By Paradigm Cooling
  • September 24, 2026
  • 0 comments

Every stage of load shedding ends the same way for a cold room or condensing unit: the power comes back, the compressor restarts, and it […]

Leave a Comment on What Load Shedding Does to Your Refrigeration Equipment
Electrical Diagnostics Technical

Why Your Compressor Keeps Tripping the Overload: Six Causes and How to Tell Them Apart

  • By Paradigm Cooling
  • September 22, 2026
  • 0 comments

A compressor that trips its overload again and again is usually not lying to you, and raising the dial is usually the wrong response. Six […]

Leave a Comment on Why Your Compressor Keeps Tripping the Overload: Six Causes and How to Tell Them Apart
Electrical Diagnostics Technical

Voltage Imbalance on Three-Phase Refrigeration: How to Measure It and When to Shut Down

  • By Paradigm Cooling
  • September 19, 2026
  • 0 comments

A three-phase compressor that trips intermittently, with every reading at rest looking perfectly normal, is one of the most commonly misdiagnosed faults in the trade […]

Leave a Comment on Voltage Imbalance on Three-Phase Refrigeration: How to Measure It and When to Shut Down
Electrical Diagnostics Technical

Ghost Voltage: Why Your Multimeter Reads 80 V on a Dead Wire

  • By Paradigm Cooling
  • September 17, 2026
  • 0 comments

You isolate a circuit, lock it off, and put a meter across two conductors you know should be dead — and it reads 80 V. […]

Leave a Comment on Ghost Voltage: Why Your Multimeter Reads 80 V on a Dead Wire
Electrical Diagnostics Technical

Insulation Resistance Testing on Compressors: What 1 MΩ Actually Means

  • By Paradigm Cooling
  • September 15, 2026
  • 0 comments

A compressor that trips its earth leakage, or fails intermittently with no other symptom, gets condemned on the strength of a single insulation resistance reading […]

Leave a Comment on Insulation Resistance Testing on Compressors: What 1 MΩ Actually Means
Electrical Diagnostics Technical

How to Test a Contactor Properly (Not the Way Most People Do It)

  • By Paradigm Cooling
  • September 12, 2026
  • 0 comments

The standard test most technicians run on a contactor — ohms across the closed contacts, looking for something near zero — passes contacts that are […]

Leave a Comment on How to Test a Contactor Properly (Not the Way Most People Do It)
Electrical Diagnostics Technical

How to Identify C, S and R Terminals on an Unmarked Compressor

  • By Paradigm Cooling
  • September 10, 2026
  • 0 comments

A replacement compressor with three unmarked terminals and no wiring diagram is a common enough job that you shouldn’t need to guess at it, and […]

Leave a Comment on How to Identify C, S and R Terminals on an Unmarked Compressor
Electrical Diagnostics Technical

How to Test a Capacitor on an Air Conditioner (And What the Reading Actually Means)

  • By Paradigm Cooling
  • September 8, 2026
  • 0 comments

A compressor or condenser fan that hums and doesn’t turn sends most technicians straight to the capacitor — and most condemn it by eye, or […]

Leave a Comment on How to Test a Capacitor on an Air Conditioner (And What the Reading Actually Means)

Recent Posts

  • Why Your TXV Is Hunting, and How to Confirm It
  • Low Superheat with High Subcooling: Reading an Overcharged System
  • High Superheat with Low Subcooling: What That Combination Means
  • Target Superheat for Fixed Orifice Systems: How to Work It Out
  • Superheat vs Subcooling: Which One Tells You What

Recent Comments

  1. Portable Air Conditioning: The Pros and Cons on Mastering Energy Consumption: A Guide to Calculating Your Air Conditioning System’s Usage
  2. Exploring the World of Refrigeration Expansion Devices on The Ultimate Guide to Air Conditioning: Everything You Need to Know
  3. Exploring Various Types of Refrigeration Compressors on Fundamentals of Refrigeration: Inside the World of Thermodynamics
  4. Harnessing the Power of Radiation: A Deep Dive on The Effects of Ambient Temperature on the Refrigerant Charge in Air Conditioning Systems
  5. The Science of Conduction: A Deep Dive into Heat Transfer on Geothermal HVAC Systems Explained: Harnessing Earth’s Energy for Efficient Heating and Cooling

Archives

  • October 2026
  • September 2026
  • January 2026
  • December 2025
  • November 2025
  • October 2025
  • September 2025
  • July 2025
  • February 2025
  • January 2025
  • December 2024
  • November 2024
  • September 2024
  • August 2024
  • July 2024
  • June 2024
  • May 2024
  • April 2024
  • March 2024
  • January 2024
  • December 2023
  • November 2023
  • October 2023
  • September 2023
  • August 2023

Categories

  • Air-Conditioning
  • Business
  • Electrical Diagnostics
  • Homeowners' guide
  • HVAC
  • HVAC tools
  • Refrigeration
  • Refrigeration Trade Test Tasks
  • Superheat and Subcooling
  • Technical
  • Uncategorized
  • YouTube Videos

You May Also Like:

Refrigeration Superheat and Subcooling

Why Your TXV Is Hunting, and How to Confirm It

A hunting TXV oscillates the evaporator between overfeeding and starving instead of settling on a stable superheat, and the fix depends entirely on which of […]

Posted on October 10, 2026 by Paradigm Cooling
Refrigeration Superheat and Subcooling

Low Superheat with High Subcooling: Reading an Overcharged System

Low superheat paired with high subcooling is the readback of a system carrying more refrigerant than it needs, and it is more dangerous to ignore […]

Posted on October 8, 2026 by Paradigm Cooling
Refrigeration Superheat and Subcooling

High Superheat with Low Subcooling: What That Combination Means

High superheat with low subcooling is the quadrant technicians get wrong most often, because the instinctive response — add gas — is correct for one […]

Posted on October 6, 2026 by Paradigm Cooling
Refrigeration Superheat and Subcooling

Target Superheat for Fixed Orifice Systems: How to Work It Out

A fixed orifice — a capillary tube or a piston — has no moving parts that respond to load, so it cannot hold superheat to […]

Posted on October 3, 2026 by Paradigm Cooling
Refrigeration Superheat and Subcooling

Superheat vs Subcooling: Which One Tells You What

Technicians who treat superheat and subcooling as interchangeable “charge check” numbers end up chasing the wrong fault half the time. Each reading answers a different […]

Posted on October 1, 2026 by Paradigm Cooling
Refrigeration Superheat and Subcooling

How to Measure Subcooling and What It Tells You

A technician who only checks superheat is diagnosing half the refrigeration circuit. Subcooling is the reading that tells you what is happening at the condenser […]

Posted on September 29, 2026 by Paradigm Cooling
Scroll to top